4.6. Configuring and Using the Logger
4.6.1. Overview
Anjay Lite provides a lightweight logging system designed for embedded environments. It is used internally by Anjay Lite itself and is also available for end user applications. This allows you to view both the library’s diagnostic messages and your application logs in a consistent format, while keeping runtime and code size overhead low.
4.6.2. Logger types
Exactly one logger type must be enabled:
Built-in handler (
ANJ_LOG_FULL)The library provides its own implementation. Log lines are formatted into a buffer, prefixed with log level, module, file and line number, and then passed to an output function.
Minimal built-in handler (
ANJ_LOG_MICRO)A minimal built-in implementation that only prefixes log lines with log level and source file ID. This mode is intended for very constrained environments where code size is critical. It has a smaller footprint than the full logger, but also provides less context in log messages.
Alternate handler (
ANJ_LOG_ALT_IMPL_HEADER)A user-provided header file defines how
anj_log()expands. This mode is meant for integrating Anjay Lite with platform loggers such as Zephyr’s logging API or other RTOS-specific systems. It requires more user setup but offers maximum flexibility and tight integration with existing logging frameworks.
4.6.3. Output backends for the built-in handler
When using the built-in handler (ANJ_LOG_FULL or ANJ_LOG_MICRO),
you must select exactly one output type:
stderr output (
ANJ_LOG_HANDLER_OUTPUT_STDERR)The library provides a default
anj_log_handler_output()implementation that writes the formatted log line tostderr.custom output (
ANJ_LOG_HANDLER_OUTPUT_ALT)The user must implement
anj_log_handler_output(const char *output, size_t len). This function receives the fully formatted log line and is responsible for transmitting it to the desired backend. This option is recommended for embedded systems, as it allows routing logs to UART, RTT, or any other interface available on the platform.
Example: minimal UART output implementation for STM32 HAL:
#include <anj/compat/log_impl_decls.h>
#include <stm32u3xx_nucleo.h>
void anj_log_handler_output(const char *output, size_t len) {
HAL_UART_Transmit(&hcom_uart[COM1], (const uint8_t *) output,
len, COM_POLL_TIMEOUT);
static const char newline[] = "\r\n";
HAL_UART_Transmit(&hcom_uart[COM1], (const uint8_t *) newline,
sizeof(newline) - 1, COM_POLL_TIMEOUT);
}
4.6.4. Alternate handler
If ANJ_LOG_ALT_IMPL_HEADER is defined, the built-in implementation is
disabled. The provided header file must define the macro
ANJ_LOG_HANDLER_IMPL_MACRO(Module, LogLevel, ...). All anj_log() calls
expand through this macro.
This approach is useful when you want to integrate Anjay Lite logging with
existing platform loggers that are also macro-based, such as Zephyr LOG_*().
Although this requires additional setup, it allows complete alignment with the
target system’s logging conventions, filtering, and runtime control.
4.6.5. Usage
Emit a log statement using the anj_log macro:
anj_log(my_module, L_INFO, "Hello %s (%d)", "world", 42);
To reduce binary size, you can wrap constant parts of log strings with
ANJ_LOG_DISPOSABLE(). If ANJ_LOG_STRIP_CONSTANTS is enabled, these
constants are replaced with a single space during compilation:
anj_log(my_module, L_DEBUG, ANJ_LOG_DISPOSABLE("Result: ") "%d", result);
4.6.6. Modules
Log statements in Anjay Lite are grouped by modules, e.g. bootstrap,
exchange, observe. When writing your own logs you can also choose a
module name. This mechanism serves two purposes:
Debugging convenience - you can enable detailed logs only for specific modules during troubleshooting.
Footprint control - increasing the log level for a single module does not increase binary size as much as enabling verbose logs globally.
4.6.7. Filtering log levels
Log levels form a hierarchy:
L_TRACE- enables all messagesL_DEBUG- enables debug, info, warning, and error messagesL_INFO- enables info, warning, and error messagesL_WARNING- enables warnings and errorsL_ERROR- enables only errorsL_MUTED- disables logging completely
The default log level is controlled by ANJ_LOG_LEVEL_DEFAULT (defaults to
L_INFO if not set). Logs below this level are removed at compile time.
For finer control, per-module overrides are possible via
ANJ_LOG_FILTERING_CONFIG_HEADER, which shall point to a user-provided header
file with per-module settings. For example:
// in my_log_filtering_config.h
#define ANJ_LOG_LEVEL_FOR_MODULE_exchange L_TRACE
#define ANJ_LOG_LEVEL_FOR_MODULE_observe L_MUTED
This configuration enables trace logs for the exchange module while completely
disabling logs in observe.
Such selective configuration makes it possible to diagnose specific problems
while keeping the binary size low.
4.6.8. Micro-logs and offline decoding
Note
Code related to this tutorial can be found under examples/tutorial/AT-MicroLogs
in Anjay Lite source directory.
4.6.8.1. Enabling micro-logs
To use micro-logs, build Anjay Lite with the minimal built-in logger enabled, i.e.
define ANJ_LOG_MICRO and disable other logger types.
set(ANJ_LOG_FULL OFF)
set(ANJ_LOG_MICRO ON)
In this configuration, the in-memory representation of log messages is very compact and uses a source file ID instead of a full file name. The file ID can later be resolved offline by the conversion script.
Example log lines in micro-log format:
INFO <ANJ_uLOG>8;152</ANJ_uLOG> Anjay Lite initialized
INFO <ANJ_uLOG>19;205</ANJ_uLOG> Device object installed
INFO <ANJ_uLOG>27;676</ANJ_uLOG> Security object installed
INFO <ANJ_uLOG>28;546</ANJ_uLOG> Server object installed
INFO <ANJ_uLOG>13;79</ANJ_uLOG> Connected to eu.iot.avsystem.cloud:5683
INFO <ANJ_uLOG>12;71</ANJ_uLOG> Registered successfully
4.6.8.2. File IDs
When using micro-logs, each C source file that emits logs must define a unique file ID. The ID must be defined before including <anj/log.h>:
#define ANJ_LOG_SOURCE_FILE_ID 201
#include <anj/log.h>
File IDs:
must be unique within the codebase,
must stay stable over time for a given file (so that previously recorded logs can still be decoded),
must not exceed
65535,must be defined as a numeric literal, not via another macro.
Important
Anjay Lite source files already define their own file IDs. When integrating
micro-logs into your application, make sure that your file IDs do not
conflict with those used by Anjay Lite - choose IDs outside the range
0-200 reserved for the library.
4.6.8.3. Decoding micro-logs with the helper script
Micro-logs are decoded outside the application using the micro_logs_decode.py
script located in the tools/ directory. The script:
scans the source tree for
ANJ_LOG_SOURCE_FILE_IDdefinitions,builds a mapping from file IDs to file paths,
reads log lines from standard input (or from a file) and prints them in a human-readable form, with reconstructed module name, file and line number.
A typical usage when running the micro-logs AT example locally is:
mkdir build
cd build
cmake ..
make anjay_lite_at_micro_logs
./anjay_lite_at_micro_logs/anjay_lite_at_micro_logs endpoint_name 2>&1 \
| ../tools/micro_logs_decode.py -r ../
In this example, the client binary is executed and its output is piped to the decoding script. Logs are decoded in real-time.
Because the example outputs logs to stderr by default, 2>&1 is used
to redirect standard error to standard output.
The -r (or --root) option specifies the project root that should be
scanned for source files. The script recursively walks this directory and its
subdirectories, looking for files that define ANJ_LOG_SOURCE_FILE_ID and
using those to resolve file IDs found in the logs.
The logs printed by the script look as follows:
INFO [src/anj/core/core.c:152]: Anjay Lite initialized
INFO [src/anj/dm/dm_device_object.c:205]: Device object installed
INFO [src/anj/dm/dm_security_object.c:676]: Security object installed
INFO [src/anj/dm/dm_server_object.c:546]: Server object installed
INFO [src/anj/core/srv_conn.c:79]: Connected to eu.iot.avsystem.cloud:5683
INFO [src/anj/core/register.c:71]: Registered successfully
The logs can also be read from a file instead of standard input by providing the -i
(or --input) option followed by the file path.
4.6.8.4. Working with serial consoles
When logs are coming from a serial console, it is often useful to:
create a named pipe to capture UART output,
open the serial console and write its output to the pipe,
feed the result to the decoder script.
One possible setup using minicom and a named pipe:
mkfifo uart_log
minicom -D /dev/ttyACM0 -C uart_log
# In another terminal:
cat uart_log | ./tools/micro_logs_decode.py
In this example: